Open-loop-Current-sensor-Transducer-NEV-application-CHK-DAB5S2L series 20 to 1000A current measuring
Open-loop-Current-sensor-Transducer-NEV-application-CHK-DAB5S2L series 20 to 1000A current measuring
Open-loop-Current-sensor-Transducer-NEV-application-CHK-DAB5S2L series 20 to 1000A current measuring
CHK- DAB5S2L
Model :
CHK- DAB5S2L
Nominal Current (RMS) :
Channel 1:± 20... ± 100;Channel 2:±200 … ±1000
Vout/Iout @Ipn :
2.5±2V
Measuring Range :
Channel 1:± 20... ± 100;Channel 2:±200 … ±1000
Supply Voltage DC :
+5V
Accuracy (%) @Ipn +25°C :
1.0
Mounting (mm) :
Ø22.5mm

Ultimate performance parameters:

PARAMETERS

SYMBOL

UNIT

VALUE

CONDITIONS

MIN.

TYP.

MAX.

Maximum supply voltage

UC

V

-14

-

14

Insulation impedance

RIS

500

-

-

500V DC-ISO 16750

Electrical safety distance

dCI

mm

3.0

Creepage distance

dCP

mm

3.0

Relative leakage index

CTI

PLC3

Maximum output current

IOUT

mA

-10

-

10

Continuous output

Maximum output voltage (analog)

V

-14

-

14

Output over voltage, 1min@25°C

General performance parameters

PARAMETERS

SYMBOL

UNIT

VALUE

CONDITIONS

MIN.

TYP.

MAX.

Power supply voltage

UC

V

4.75

5

5.25

Current consumption

IC

mA

-

15

20

@TA = 25°C, Uc = 5V

Output current

IC

mA

-1

1

Load resistance

RL

10

-

Output impedance

ROUT

Ω

1

-

10

Capacitive load

CL

nF

1

-

100

Working temperature

TA

-40

125

Performance parameter channel 1:

Rated measurement current

IPN

A

-

-

According to model:

± 20... ± 100

Zero voltage

UO

V

2.5

@Uc = 5V

Rated output 1)

Uout

V

Uout = (UC/ 5) × (Uo + S × IP )

@TA = 25°C

Sensitivity

S

mV/A

-

2000/IPN

-

@Uc = 5V

Minimum output clamp voltage

USZ

V

0.2

0.25

0.3

@Uc = 5V

Maximum output clamp voltage

4.7

4.75

4.8

@Uc = 5V

Proportional error

εr

%

-0.6

0.6

Sensitivity error

εS

%

±0.4

@TA = 25°C

±1.0

@-10°CA<65°C

±1.5

@-40°CA<125°C

Electronic offset voltage range

UOE

mV

±10

@TA = 25°C,Uc=5V

Magnetic offset voltage range

UOM

mV

±5

@TA = 25°C,Uc=5V,after ±IP

Linearity error

εL

%

-

±0.5

-

@TA = 25°C,Uc=5V

Zero voltage temperature coefficient

TCUO

E AV

mV/℃

-0.1

Need Help
You have a Measurement problem, we have the Sensing solution.
CONTACTS

Tel:+86(0)25-8599 6365
MP:+86-188 5113 2317
anna.lei@cheemi-tech.com
WhatsApp: +86-188 5113 2317
Wechat: 18824256810
3/F, Building 6, Jingang Science and Technology Innovation Park, No.1 Kechuang Road, Qixia District, Nanjing, China.

Copyright © 2015-2023 CHEEMI TECHNOLOGY CO., LIMITED. All Rights Reserved. Current Sensors Sitemap